Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Journal of Experimental Hematology ; (6): 1301-1307, 2021.
Article in Chinese | WPRIM | ID: wpr-888556

ABSTRACT

OBJECTIVE@#To understand the characteristics of patients with mimicking specificity autoantibodies through the analysis of the causes of autoantibodies, specificity of antibodies, strategy of blood transfusion, effect of transfusion and distribution of antibodies in China and abroad.@*METHODS@#A total of 23 patients who applied for blood in our hospital from January 2017 to June 2019 were identified as mimicking specificity autoantibodies by antibody identification or absorption-elution test. The causes of mimicking specificity autoantibodies, antibody specificity, blood transfusion strategy and blood transfusion effect were analyzed. The relevant articles on antibodies published in China and abroad were summarized and sorted out, and the distribution of antibodies was analyzed.@*RESULTS@#All the 23 patients with mimicking specificity autoantibodies were Rh blood group system antibodies, of which mimicking anti-Ce autoantibodies were the most common (34.8%), followed by mimicking anti-e autoantibodies (26.1%), mimicking anti-D autoantibodies (21.7%), mimicking anti-C autoantibodies (8.7%) and mimicking anti-E autoantibodies (8.7%). Except for 2 cases with suspected history of blood transfusion, the other 21 cases had a history of blood transfusion / pregnancy. The most common cause of mimicking autoantibodies was drug, followed by infection and autoimmune diseases. The hemoglobin (Hb) of pretransfusion in the blood transfusion group was (48.4±23.9) g/L, which was significantly lower than (86.0±38.9) g/L in the non-transfusion group (P<0.01). Except for 2 cases who could not evaluate the effect of blood transfusion, the effective rate of transfusion was 100%. According to the retrospective statistics of 32 related articles published in China and abroad, the most type of mimicking antibodies were in Rh blood group system, accounting for 79.28%, among which anti-E was the main part of all mimicking autoantibodies, accounting for 21.95%. The following ones were in Kidd system MNSs system, and Kell system.@*CONCLUSION@#Combined with the clinical symptoms and the degree of difficulty of blood matching, the best strategy of blood transfusion should be selected to ensure the safety of blood transfusion.


Subject(s)
Female , Humans , Pregnancy , Autoantibodies , Blood Group Antigens , Blood Transfusion , Isoantibodies , Retrospective Studies
2.
Journal of Experimental Hematology ; (6): 904-908, 2020.
Article in Chinese | WPRIM | ID: wpr-827187

ABSTRACT

OBJECTIVE@#To evaluate the characteristics of autoimmune hemolytic anemia caused by salvianolate by antibody detection and clinical index monitoring.@*METHODS@#Micro-column gel anti-human globulin method was used for irregular antibody screening and antibody identification. Salvianolate, sodium creatine phosphate and levocarnitine were used to sensitize red blood cells that were compatible with the patient's plasma, and the RBCs were used to test drug antibody in patient plasma respectively. The patient's clinical examination of hemolysis index and blood transfusion effect were analyed retrospectively.@*RESULTS@#The patients were positive for irregular antibody screening, and there were antoanti-Ce antibodies in serum. The erythrocytes sensitized with salvianolate in the patient's serum were positive, while those sensitized with sodium creatine phosphate and levocarnitine were negative.@*CONCLUSION@#Salvianolate causes drug-induced autoimmune hemolytic anemia in this patient.


Subject(s)
Humans , Anemia, Hemolytic, Autoimmune , Blood Transfusion , Erythrocytes , Plant Extracts , Retrospective Studies
3.
Journal of Experimental Hematology ; (6): 1081-1086, 2015.
Article in Chinese | WPRIM | ID: wpr-274089

ABSTRACT

<p><b>OBJECTIVE</b>To investigate the factors influencing platelet transfusion results so as to improve the platelet transfusion efficiency.</p><p><b>METHODS</b>According to the clinical symptoms (bleeding condition is stopped or improved)and the corrected count of increment (CCI), the patients were divided into efficient transfusion and inefficient transfusion groups. A total of 20 671 patients' clinical data and main platelet transfusion parameters in 26 045 tranfusions including platelet count of per- and post- transfusion, platelet component sorts, storage time and transfusion number were analysed.</p><p><b>RESULTS</b>The comparison of platelet transfusion efficiency in age and sex between two groups did not showed statistical difference (P > 0.05), the platelet count before transfusion between two groups showed statistical difference (t = -5.59, P < 0.001) after converting to log, a significant linear correlation did not exist between storage time of the platelet and CCI (corrected count of increment), but there was statistical difference in transfusion efficiency of patients with different diseases. The patients with hematologic diseases showed lower efficiency of platelet transfusion. According to the results of Wilcocon test detection, there was difference between different times of transfusion and transfusion efficiency, that is to say, the transfusion frequency was higher, the transfusion efficency was lower. The Fisher test indicated that the transfusion efficiency of single platelet transfusion was lower than that of transfussed platelet with other blood components (P < 0.01).</p><p><b>CONCLUSION</b>Platelet transfusion efficiency associates with many factors, including different diseases, whether being transfused with other blood components, the platelet count before transfusion, transfusion frequency, but the time of storage does not relate to the transfusion efficacy.</p>


Subject(s)
Humans , Blood Platelets , Hematologic Diseases , Platelet Count , Platelet Transfusion
4.
Journal of Experimental Hematology ; (6): 1478-1482, 2015.
Article in Chinese | WPRIM | ID: wpr-274012

ABSTRACT

<p><b>OBJECTIVE</b>To evaluate the effects of the 25 Gy ⁶⁰Co irradiation on the physiological and biochemical properties and the functions of the platelets during storage.</p><p><b>METHODS</b>A total of 15 bags of platelets were apheresis-collected from 15 healthy donors, and each bag of platelets were divided into 2 parts, then the platelets were divided into the control group (without 25 Gy ⁶⁰Co irradiation) and the irradiated group (with 25 Gy ⁶⁰Co irradiation) groups. The two groups of platelets were kept under the condition of (22 ± 2) °C and shaken. The Platelet count and pH value were detected on the d 1, d 2, d 3, d 4 and d 5. The variables such as R, K values, α angle and maximal amplitude (MA) were measured by thrombelastography on the same days. Hypotonic shock response (HSR), morphological score were devised.</p><p><b>RESULTS</b>There were no statistically significant difference in Plt counts, mean platelet volume (MPV), platelet distribute width (PDW) and pH between the two groups (P > 0.05), and Plt count decreased on the end of storage. There were no marked changes in HSR level and morphological score between the two groups during storage, and there were no significant difference between the two groups (P > 0.05). In the TEG analysis there were no significant difference of the R, K, α angle and MA values between the two groups (P > 0.05). R value showed upward trend increased along with prolongation of preserved time (P < 0.01), no significant changes in α angle (P > 0.05), K value was slightly higher and MA value was lower in the last day of storage than the days 1-4 (P < 0.01), respectively.</p><p><b>CONCLUSION</b>25 Gy ⁶⁰Co gamma-ray irradiation can not damage the physiological, biochemical properties and the functions of the platelets during storage. In order to ensure the best curative effect, it is suggested that no matter the platelets were irradiated or not, the platelets should be used as soon as possible.</p>


Subject(s)
Humans , Blood Platelets , Radiation Effects , Blood Preservation , Gamma Rays , Platelet Count
5.
Journal of Experimental Hematology ; (6): 1275-1279, 2013.
Article in Chinese | WPRIM | ID: wpr-283938

ABSTRACT

This study was aimed to analyze the serological characteristics, efficacy and safety of incompatible RBC transfusion in patients with autoimmune hemolytic anemia (AIHA). The patients with idiopathic or secondary AIHA were analyzed retrospectively, then the serological characteristics and the incidence of adverse transfusion reactions were investigated, and the efficacy and safety of incompatible RBC transfusion were evaluated according to the different autoantibody type and infused different RBC components. The results showed that out of 61 cases of AIHA, 21 cases were idiopathic, and 40 cases were secondary. 8 cases (13.1%) had IgM cold autoantibody, 50 cases (82.0%) had IgG warm autoantibody, and 3 cases (4.9%) had IgM and IgG autoantibodies simultaneously. There were 18 cases (29.5%) combined with alloantibodies. After the exclusion of alloantibodies interference, 113 incompatible RBC transfusions were performed for 36 patients with AIHA, total efficiency rate, total partial efficiency rate and total inefficiency rate were 56.6%, 15.1% and 28.3%, respectively. Incompatible RBC transfusions were divided into non-washed RBC group and washed RBC group. The efficiency rate, partial efficiency rate and inefficiency rate in non-washed RBC group were 57.6%, 13.0% and 29.4%, respectively. The efficiency rate, partial efficiency rate and inefficiency rate in washed RBC group were 53.6%, 21.4% and 25.0%, respectively. There was no significant difference of transfusion efficacy (P > 0.05) in two groups. Incompatible RBC transfusions were also divided into IgM cold autoantibody group and IgG warm autoantibody group. The efficiency rate, partial efficiency rate and inefficiency rate in IgM cold autoantibody group were 46.2%, 30.8% and 29.4%, respectively. The efficiency rate, partial efficiency rate and inefficiency rate in IgG warm autoantibody group were 56.7%, 13.4% and 29.9%, respectively. There was no significant difference of transfusion efficacy (P > 0.05 ) in two groups. Hemolytic transfusion reaction was not observed in all incompatible RBC transfusions. It is concluded that the same ABO type of non-washed RBC transfusion and O type washed RBC transfusion are all relatively safe for the AIHA patients with severe anemia after the exclusion of alloantibodies interference. There is no significant difference of transfusion efficacy in two groups. The same ABO type of non-washed RBC transfusion is more convenient and efficient than washed RBC transfusion, and excessive use of type O RBCs can also be avoided.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Anemia, Hemolytic, Autoimmune , Diagnosis , Allergy and Immunology , Therapeutics , Blood Grouping and Crossmatching , Erythrocyte Transfusion , Isoantibodies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL